ACI 3189.6

Minimum flexural reinforcement (beams)

Minimum reinforcement greater of 3√f'_c × b_w × d / f_y or 200 × b_w × d / f_y, in psi units. Prevents brittle failure at first cracking.

Apply this clause

Open Section Design to run this check against your own input.

Open Section Design